Search results for "parallel graft"

showing 5 items of 5 documents

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…

2013

Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…

aortic aneurysm pararenal aortic aneurysm thoracoabdominal aortic aneurysm aortic arch endovascular aneurysm repair renal artery superficial mesenteric artery celiac trunk target vessel stent-graft side branch chimney graft periscope graft parallel graft target vessel patency endoleak side branch occlusionSettore MED/22 - Chirurgia Vascolare
researchProduct

Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery

2014

Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…

Adultmedicine.medical_specialtyTime FactorsAortic RuptureCardiovascular AbnormalitiesSubclavian ArteryHemodynamics610 Medicine & healthProsthesis DesignAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationBlood vessel prosthesisX ray computedmedicine.arterymedicineHumansThoracic aorta2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingcardiovascular diseasesEndovascular treatmentAortabusiness.industryEndovascular ProceduresHemodynamicsAberrant right subclavian arteryVascular System InjuriesAneurysmBlood Vessel ProsthesisSurgery10020 Clinic for Cardiac Surgery2746 SurgeryTreatment Outcomesurgical procedures operativeRegional Blood FlowLanding zonecardiovascular systemStentsSurgeryAneurysm surgeryRadiologyDeglutition DisordersTomography X-Ray ComputedCardiology and Cardiovascular Medicinebusinessthoracic aorta aortic transection trauma thoracic endovascular aortic repair aberrant right subclavian artery left subclavian artery stent-graft parallel graft chimney graft periscope graft landing zone
researchProduct

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

2017

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

MaleTime FactorsEndoleakComputed Tomography Angiographymedicine.medical_treatmentMid term resultsKaplan-Meier Estimate030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsOcclusionMedicine030212 general & internal medicineAortic arch aneurysm; Chimney graft/technique; Endoleak; Endovascular aneurysm repair; Parallel graft; Periscope graft; Surgery; Cardiology and Cardiovascular MedicineAged 80 and overeducation.field_of_studyHigh risk patients10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryTreatment Outcomecardiovascular systemFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyPopulation610 Medicine & healthProsthesis DesignAortographyRisk AssessmentDisease-Free Survival2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationEndovascular aneurysm repair03 medical and health sciencesAneurysmmedicine.arteryHumanseducationAgedRetrospective StudiesAortaAortic Aneurysm ThoracicParallel graftAortic arch aneurysmbusiness.industryPatient SelectionChimney graft/techniquemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac SurgerySurgeryPeriscope graftSurgerybusinessEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results

2018

Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…

MaleTime Factorsabdominal aortic aneurysm; chimney graft; chimney technique; endoleak; endovascular aneurysm repair; juxtarenal aortic aneurysm; parallel graft; pararenal aortic aneurysm; periscope graft; snorkel graftmedicine.medical_treatmentJuxtarenal aortic aneurysm030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repair0302 clinical medicineRisk FactorsRetrospective analysisChimneyRegistries030212 general & internal medicineAged 80 and overEndovascular ProceduresChimney graftAbdominal aortic aneurysmEuropeTreatment Outcomesnorkel graftFemaleStentsjuxtarenal aortic aneurysmCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyparallel graftendoleakperiscope graftProsthesis Designpararenal aortic aneurysmBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmchimney techniquemedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industrychimney graftmedicine.diseaseUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct